Technical Parameters
| Items | Technical Parameters |
| Executive Standard | GB25280-2010 |
| Working Voltage | AC110V/220V±20% (changed by switch) |
| Working Frequency | 47Hz~63Hz |
| No-load power | ≤15W |
| The whole controller rated load power | 2200W |
| Motor operation sequence(special timing state should be statement before production) | all Red(can setup) →green light→green flash can setup) →yellow light→Red light |
| Pedestrian signal operation sequence | all Red(can setup) →green light→Green flash(can setup)→Red light |
| Rated drive current in each way | 3A |
| Surge current in each way | ≥100A |
| Maximum independent output channels | 22 |
| Maximum independent phase | 8 |
| Adjustable menus | 16 |
| Can be setup menus number | 30 |
| The largest number of each menu | 24 |
| The largest number of timers in each day | 24 |
| Running time in each step | 1~255 |
| Full red transition time | 0~5S |
| Yellow light transition time | 1~9S |
| Green flashing time | 0~9S |
| Operational Temperature Range | -40℃~+80℃ |
| Relative Humidity | <95% |
| Setting Saving Time(the electricity was cut off) | 10 years |
| Time Error | Error/year<2.5 minutes (25±1℃) |